A second PDK: IHP SG13G2

Reticle’s generators were written against the SKY130 subset, but the process numbers they draw against are data, not baked constants. This chapter describes that data-driven design (GenTech) and the second process it enables: IHP’s open SG13G2 (a 130 nm SiGe BiCMOS process).

GenTech: numbers as data

Every generator needs the same small set of per-process numbers: the interconnect conductors it may route on (each with a minimum width, spacing, and optional minimum area), the cut layers that bridge adjacent conductors (each with an exact drawn size and the enclosure a covering plate owes it), the substrate-tap contact under the base conductor, and a conservative cut pitch for layers whose deck carries no cut-to-cut spacing. GenTech gathers exactly those into one value.

The generators read GenTech from the Technology argument threaded into generate() (GenTech::for_technology, which selects a built-in by process name and defaults to SKY130 so every existing caller is unaffected). The ring / serpentine / fill / via-array topology, the parameter schemas, and the validation stay code; only the numbers are data. GenTech::sky130() is authored from the committed SKY130 subset and cross-checked against reticle_drc::sky130_drc_rules() by test; a derive_gentech() function reconstructs a GenTech from any parsed Technology, proving the values are faithful to the deck (and to the stack ordering). See ADR 0084.

Roles, not layer names

A GenTech is four stacked interconnect conductors (index 0 = base), three cuts where cut[i] bridges conductor[i] and conductor[i+1], and one substrate-tap cut. The generators address these by role (level index), so a generator enum variant like RingLayer::Li1 means “the base interconnect” - li1 on SKY130 and Metal1 on SG13G2. The role binding for the two processes this chapter was written about (a third, GF180MCU, was retargeted the same way afterwards: GenTech::gf180 in crates/reticle-gen/src/gentech.rs, DRC deck crates/reticle-drc/src/gf180.rs, data files tech/gf180.tech and tech/gf180-drc-subset.toml):

roleSKY130SG13G2SG13G2 GDS
conductor 0li1Metal18/0
conductor 1met1Metal210/0
conductor 2met2Metal330/0
conductor 3met3Metal450/0
cut 0 (0↔1)mconVia119/0
cut 1 (1↔2)viaVia229/0
cut 2 (2↔3)via2Via349/0
substrate taplicon1Cont6/0

The SG13G2 data and its provenance

tech/ihp-sg13g2.tech carries the layer table, the physical stack, and the DRC subset inline; tech/sg13g2-drc-subset.toml is the cited source of record. Every number is transcribed from the open IHP-Open-PDK (github.com/IHP-GmbH/IHP-Open-PDK, branch main, Apache-2.0), with the KLayout DRC rule ids preserved (e.g. M1.a, V1.c). The subset mirrors the digital routing stack (Metal1–Metal4 width/spacing, the Cont/Via1–3 sizes and via enclosures) and deliberately omits what the generators do not draw against: the wide-metal and pattern-density spacing variants (which the DRC engine cannot express as width-conditional), the FEOL Activ/GatPoly contact enclosures, and the thick TopMetal stack. Passing it is not tape-out clean. See ADR 0085.

The proof: all three PDKs, clean by construction

The cleanliness oracle runs every generator over all three shipped processes (crates/reticle-gen/tests/second_pdk.rs for SKY130 and SG13G2, crates/reticle-gen/tests/third_pdk.rs for GF180MCU): it samples random valid parameters, generates into a fresh cell using each process’s Technology, and asserts the real DRC engine finds zero violations under that process’s own deck. CORRECTED 2026-07-31: this said “both processes” while README.md already said “three real PDKs”. Check: git ls-files crates/reticle-gen/tests/second_pdk.rs crates/reticle-gen/tests/third_pdk.rs. The same generator code, handed a different technology by name, draws against that process’s own layers and numbers and stays clean. Making this hold for the second process took exactly one generator change - the contact chain now encloses each contact by both bridging conductor levels, so whichever level a process’s deck requires to enclose the cut (met1 encloses mcon on SKY130, Metal1 encloses Via1 on SG13G2) is satisfied. Everything else was already portable once the numbers became data.